EasyManuals Logo
Home>Emerson>Controller>Affinity

Emerson Affinity User Manual

Emerson Affinity
274 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #163 background imageLoading...
Page #163 background image
Safety
Information
Product
Information
Mechanical
Installation
Electrical
Installation
Getting
Started
Basic
parameters
Running
the motor
Optimization
SMARTCARD
operation
PC tools
Advanced
parameters
Technical
Data
Diagnostics
UL Listing
Information
Affinity User Guide 163
Issue Number: 5 www.controltechniques.com
11.6 Menu 6: Sequencer and clock
Figure 11-9 Menu 6 logic diagram
6.12
Keypad
STOP
1.11
Reference
enabled
indicator
1.12
Reverse
selected
indicator
1.13
Jog
selected
indicator
RUN
STOP/
RESET
FWD/REV
RESET
1.49
Reference
selected
indicator
Logic 1
Open loop only
6.06
Injection
braking level*
6.07
Injection
braking time*
6.17
Power
consumption
meter reset
6.21
Time
interval
between
filter changes
6.22
Filter
change
required/done
6.27
Electricity cost
per kWh
Clock control
Time before filter
change due
6.28
Running
cost
6.23
Power meter
Inverter enable
RFC only
Menu 2
Menu 3
Ramp
Hard speed
reference
enable
enable
5.03
Total motor
power
0.XX
0.XX
Key
Read-write
(RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
The parameters are all shown at their default settings
Pr = 4
1.49
01
Sequencer
6.01
6.03
6.08
6.09
6.40
Stop mode
*selector
Line power supply
loss mode**
Hold zero speed/
Motor pre-heat
*****enable
Catch a
spinning motor***
Enable sequencer
latching
5.05
DC bus voltage
Low voltage supply
Drive power supply monitor
6.44
Active supply
6.18
6.17
Time
Day of
week
6.16
Date
6.19
Date/time
selector
0
1
2
3
4
5
Power up time
Slot 1 RTC
Slot 2 RTC
Internal RTC
Run time
Set time
6.25
6.26
Pr = 0
1.52
6.15
6.30
6.31
6.32
6.33
6.42
6.34
6.37
6.43
Jog reverse
Run
Forward / Reverse
Run reverse
Jog forward
Run forward
Drive enable
Control word
Control word
enable
6.35
6.36
Limit switch 2
Limit switch 1
6.29
Hardware
enable
Menu 8
6.04
Stop / Start
***select
T25 digital I/O 2
T26 digital I/O 3
T27 digital input 4
6.39
Not stop
Fire mode
active
0
1
1
0
0
0
0
0
0
0
0
0
6.49
Enable date / time
in trip log

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Affinity and is the answer not in the manual?

Emerson Affinity Specifications

General IconGeneral
BrandEmerson
ModelAffinity
CategoryController
LanguageEnglish

Related product manuals