EasyManuals Logo

FAAC E124 User Manual

FAAC E124
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
E124 18 532365 - Rev.A
Translation of the original instructions
ENGLISH
3 Advanced programming menu
The DEFAULT settings for the type of automation are indicated in the corresponding column (e.g. column
4 for S418).
Advanced function DEFAULT:
0 1 2 3 4 5 6 7
bo
MAXIMUM FORCE AT INITIAL THRUST TIME When it starts, the motor
operates at maximum power for the time set in this option.
0110 s Adjustment step: 1 s.
02 02 02 02 02 02 02 03
cS
CLOSING THRUST This function assists the closing of the electric lock: it
pushes against the closing stop with maximum force for 2 s. DO NOT enable
the function if there is not a mechanical closing stop fitted.
Y enabled, no disabled (* = not modifiable if FC = 1)
no*
rS
REVERSE STROKE FOR OPENING NOT displayed if FC = 1.
This function assists the release of the electric lock: it pushes against the
closing stop for 2 s before opening. DO NOT enable the function if there is
not a mechanical closing stop fitted.
The reverse stroke is NOT compatible with the closing stop limit switch, for this
reason it is not carried out if, after enabling it, you set
FC = 1.
Y enabled, no disabled
no
EL
ELECTRIC LOCK ON LEAF 2 NOT displayed if Mn = 1. This function has
to be enabled if the electric lock is installed on Leaf 2 (it is usually on Leaf 1).
Y enabled, no disabled
no
Od
LEAF OPENING DELAY NOT displayed if Mn = 1. This delay is applied
to Leaf 2.
0059 s Adjustment step: 1 s The display subsequently changes to
minutes and tens of seconds (separated by a point), up to a maximum of
1.3
minutes. E.g.
1.2 = 1 min and 20 s.
1.01.3 Adjustment step: 10 s
02
IP
REVERSE ON OBSTACLE This function specifies the amount the leaf is
reversed after an obstacle has been detected.
Y = partial reverse (for 2 s), no = complete reverse
no
r1
LEAF 1 DECELERATION NOT displayed if FA and FC = 2. Specifies
the deceleration space for Leaf 1 (% of the total stroke).
0099 % Adjustment step: 1 %
30 30 30 20 30 20 30 30
r2
LEAF 2 DECELERATION NOT displayed if Mn = 1 , or
if
FA and FC = 2. Specifies the deceleration space of Leaf 2 (% of the
total stroke).
0099 % Adjustment step: 1 %
30 30 30 20 30 20 30 30
PF
PRE-FLASHING Enables/disables pre-flashing and specifies when it is
activated. The pre-flashing time is fixed: 3 s.
no
no disabled
OC for any movement
CL when closing
OP when opening
PA when the pause time elapses
Ph
CLOSING PHOTOCELLS Specifies the operation of the closing photocells.
Y reopen when the photocells disengage
no reopen immediately
no

Table of Contents

Other manuals for FAAC E124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FAAC E124 and is the answer not in the manual?

FAAC E124 Specifications

General IconGeneral
ModelE124
CategoryControl Unit
Maximum Motor Current5 A
Operating Temperature-20°C to +55°C
Operating Voltage230V AC
Protection DegreeIP55
Power Supply230V AC (+6% -10%) 50 (60) Hz

Related product manuals