E124 39 532365 - Rev.A
Translation of the original instructions
ENGLISH
10. OPERATION
ACCESSORIES
LED
Lights up during opening and stays on as long as the
automation remains open. Flashes during closing. It
is off when the automation is closed.
COURTESY LIGHT
Lights up during movements and remains on for the
set time (
t1).
TRAFFIC LIGHT CONTROL
It lights up when the automation is opening and stays
on as long as it remains open.
OPERATING LOGICS
L
the STOP command has priority in all the logics and
stops the automation.
The CLOSE command always closes the automation.
E SEMIAUTOMATIC
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to open.
OPEN if the automation is open, causes it to close.
OPEN during opening, stops the gate and the next
OPEN command closes it.
OPEN during closing, causes it to reopen.
The triggering of the photocells during movement, re-
verses the gate.
EP SEMIAUTOMATIC STEPBYSTEP
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to open.
OPEN if the automation is open, causes it to close.
OPEN during opening or closing, stops the gate and
the next OPEN command reverses the direction.
The triggering of the photocells during movement, re-
verses the gate.
S AUTOMATIC SAFETY
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to
open. The automation closes automatically after the
pause time has elapsed.
OPEN during opening, causes it to close.
OPEN during pause, causes it to close.
OPEN during closing, causes it to reopen.
The triggering of the closing photocells during pause, closes
the gate - during opening, requests closing, - during
closing, causes the gate to reverse and then closes it
immediately.
COMMANDS
OPEN A TOTAL MOTION
Total motion is 100% of the length of travel. In 2-leaf
automations, Leaf1 starts opening first (if the delay is
programmed).
OPEN B PARTIAL MOTION
In single leaf automations, partial motion is 50% of
the length of travel.
In 2-leaf automations, partial motion is 100% of the
length of travel of Leaf1. Leaf1 starts opening first (if
the delay is programmed).
STOP STOPS UNTIL THE BUTTON IS RESET.
BATTERY OPERATION IF PRESENT
When there is no mains power, the automation oper-
ates on battery until the charge level drops to the
threshold value: 16 V
"
.
WARNING The frequency at which the flashing light
flashes increases with every movement carried out in
battery operation mode. A warning can be also be
programmed on a dedicated output.
SLEEP mode If the charge drops to the threshold
value, the board goes into SLEEP mode: automation
NOT operational, display off, IN LED flashing every 4
s. Normal operation resumes when the mains sup-
ply is restored.
DETECTION DEVICES
CLOSING PHOTOCELLS
The triggering of the photocells during closing, causes
the gate to open. An alternative operation can be
configured using function
Ph in Advanced program-
ming: the triggering of the photocells stops the gate
immediately and opens it when they are released.
If they are engaged when the leaves are stationary, the closing
photocells prevent the gate from closing until they are released.
OPENING PHOTOCELLS
If the photocells are triggered, the automation is
stopped.
OPENING/CLOSING PHOTOCELLS
If the photocells are triggered, the automation is
stopped.
SENSITIVE EDGE SAFETY
If an obstacle is detected during opening or closing,
the leaf reverses for 2 s and then the automation stops.
OBSTACLE DETECTION BY BOARD OR ENCODER
If an obstacle is detected during opening or closing,
the leaf reverses (ANTI-CRUSHING), then the automa-
tion stops.

Table of Contents

Other manuals for FAAC E124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FAAC E124 and is the answer not in the manual?

FAAC E124 Specifications

General IconGeneral
ModelE124
CategoryControl Unit
Maximum Motor Current5 A
Operating Temperature-20°C to +55°C
Operating Voltage230V AC
Protection DegreeIP55
Power Supply230V AC (+6% -10%) 50 (60) Hz

Related product manuals