INSTALLER VENTILATION INLETS tab page Tunnel
Setting of the name of the function.
Setting of the analog output address.
Setting indicating the analog control type
Setting if the air inlet is open or closed during this phase.
FOLLOW COMBI: according to the percentage in the combi-table (normal setting).
CLOSED: close (the curtain at the side of house where the fans are placed must be
closed during mechanical ventilation).
CLOSED UNTIL: close until a certain combi step, from this step the inlet will follow
the combi-table.
Setting indicating if the extra inlets have to be open or closed during natural ventilation.
CLOSED: close (normal setting)
FOLLOW NAT.: if this air inlet must follow the natural curtain (e.g. tunnel curtains
which also have to open during natural ventilation).
Setting of the time in which the air inlets go to the required position, before the fans
activate.
Setting indicating if these air inlets are to be included in modulating ventilation — if
modulating ventilation is used.
Setting of the compass positions, which represent the wind side of the house. If the
wind comes from this direction (positions), the ventilation control may be influenced.
Setting of the compass positions, which represent the lee side of the house. If the wind
comes from this direction (positions) under wind side, the ventilation control may be
influenced.