Special formats
LOCATION 18 - CUSTOM COMMUNICATOR FORMAT (see locations 2, 8, and 14)
Segment 1
1 = On for 1800hz transmit; Off for 1900hz
2 = On for 2300hz handshake; Off for 1400hz
3 = On for checksum parity; Off for double round parity
4 = On for 2 digit event code; Off for 1 digit event code
5 = On for extended reporting; Off for non-extended reporting
6 = Reserved
7 = On for 20 PPS; Off for 10 or 40 PPS
8 = On for 10 PPS; Off for 20 or 40 PPS
Segment 2
1 = On for pager format (no handshake required).
2 = On for 1400/2300 handshake
3 = Reserved
4 = Reserved
5 = On for Contact ID
6 = On for SIA
7 = On for 3 digit event code
8 = On for DTMF
Segment 3
Reserved
Segment 4
Inter-digit time for pulse format:
The inter-digit time is the value programmed on this location, divided by the
pulse-rate (PPS) of the programmed format. This is programmed in a binary
way: in order to program the value “10”, options 2 and 4 must be selected,
for value “5”, options 1 and 3 must be selected.
Ex: when the value 10 is programmed on segment 4 and a pulse format of
20 PPS is used, the inter-digit time is 10/20 = 0.5 sec.
NX-4-EUR Installation manual Page 42 02/07/06