Segment 5
1 = On: Disables auto-bypassing of force armable zones at the end of the
exit delay
2 = Reserved
3 = Reserved
4 = Reserved
5 = Reserved
6 = Reserved
7 = Reserved
8 = Reserved
Entry/Exit timers
LOCATION 24 - ENTRY / EXIT TIMERS (6 segments, numerical data)
Location 24 is used to program the entry/exit times. There are 2 separate entry/exit times.
Segment 1
Entry time 1 This is the entry time that will be used when a delay 1
zone type initiates an entry delay.
Valid entries are 10-255 seconds.
Segment 2
Exit time 1 This is the exit time that will be used for all zones
designated as delay 1.
Valid entries are 10-255 seconds.
Segment 3
Entry time 2 This is the entry time that will be used when a delay 2
zone type initiates an entry delay.
Valid entries are 10-255 seconds.
Segment 4
Exit time 2 This is the exit time that will be used for all zones
designated as delay 2.
Valid entries are 10-255 seconds.
Segment 5
Reserved
Segment 6
Reserved
NX-4-EUR Installation manual Page 45 02/07/06