APPENDIX 2: REPORTING ZONE CODES IN SIA OR CONTACT
ID
The NX-4 has the ability to report SIA level 1 transmissions to either or both phone numbers. Each report in SIA
consists of an Event Code and a Zone or User ID. The Zone ID will be the zone number that is in alarm. The event
code will come from the chart below, and it will be programmed in the configuration group event code.
Programmed Event Code SIA Code Description
0 HA Holdup Alarm
1 FA Fire Alarm
2 PA Panic alarm
3 BA Burglary Alarm
4 BA Burglary Alarm
5 BA Burglary Alarm
6 UA Untyped Alarm
7 BA Burglary Alarm
8 BA Burglary Alarm
9 UA Untyped Alarm
10 HA Holdup Alarm
11 MA Medical Alarm
12 PA Panic alarm
13 TA Tamper Alarm
14 RP Periodic Test
15 GA Gas Alarm
16 KA Heat Alarm
17 WA Water Alarm
18 QA Emergency Alarm
19 SA Sprinkler Alarm
20 ZA Freeze Alarm
21 KH Heat Alarm Restore
22 FA Manual Fire Alarm
NX-4-EUR Installation manual Page 89 02/07/06