PACE Series SCPI Manual
K0472 Revision A 4-99
:STAT:OPER:ENAB
Applicability: PACE1000, PACE5000, PACE6000
Command Syntax
:STATus:OPERation:ENABle <integer>
Parameter: <integer> 16 bit value to set enable bits
Short form: STAT:OPER:ENAB <integer>
Function: Controls the status operation enable register.
Default: 0
minimum 0
maximum 32767
Query Syntax
:STATus:OPERation:ENABle?
Short form: :STAT:OPER:ENAB?
Function: Query enable register
Response: 16 bit value of enable register.
Description
Controls the bits that pass through the status reporting system, see status reporting section.