9. Maintenance
PNEG-750-G2 16" Series II Sweep 131' and 135' Diameter 65
Lubrication
A. Lubrication – Electric Motors
Electric motors supplied for use on Series II Sweeps are properly lubricated at the time of manufacture.
It is not necessary to lubricate them at the time of installation unless the motor has been in storage for
one year or longer. Some motors may be factory lubricated and sealed for the life of the bearings.
Overgreasing the bearings can cause premature failure of the motor. The amount of grease added
must be carefully controlled.
B. Procedure for Lubrication of Electric Motors
1. Stop motor. Disconnect and lock out of service.
2. Follow all safe bin entry procedures and wear all required personal protective equipment.
3. Remove contaminants from grease inlet area.
4. Remove filler and drain plugs.
5. Check filler and drain holes for blockage and clean as necessary.
6. Add proper type and amount of grease. See Chart below and on Page 66 for amount of
lubricant. Too much grease or injecting grease too quickly can cause premature bearing
failure. Use approximately one minute to slowly inject the recommended amount of grease.
7. Wipe off excess grease and replace filler and drain plugs. Do not run motor without the
grease and drain plugs installed.
NOTE: It is very important to keep the grease clean. Mixing dissimilar grease is not recommended.
C. Type of Lubrication
A polyurea mineral oil NGLI grade 2 type grease is to be used for lubrication of the electric motors.
Grease meeting this specification include:
D. Frequency of Lubrication
Motors should be relubricated after storage of one year or more or at the beginning of each season.
The following Chart gives the amount of grease to be added.
Lubrication - Electric Motors
Quantity of Grease per Frame Size
1. Chevron SRI #2
2. Exxon-Mobile Polyrex EM
3. Texaco Polystar RB
For Baldor Brand Electric Motors
NEMA
Frame Size
Volume
Cu. in. Fluid oz
56C
143TC 0.25 0.14
182TC 0.5 0.28
184TC 0.5 0.28
213T 0.75 0.42
215T 0.75 0.42
254T 1 0.55
256T 1 0.55
284T 1.25 0.69
286T 1.25 0.69
324T 1.5 0.83

Table of Contents

Other manuals for GSi Sweep II Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GSi Sweep II Series and is the answer not in the manual?

GSi Sweep II Series Specifications

General IconGeneral
BrandGSi
ModelSweep II Series
CategoryFarm Equipment
LanguageEnglish

Related product manuals