The door remains open for the congured me duraon aer the rst person is authorized
unl the remain open duraon ends. If you select this mode, you should set the remain open
duraon.
Note
The remain open duraon should be between 0 and 1440 minutes. By default, the remain
open duraon is 10 minutes.
Disable Remaining Open aer First Person
Disable the funcon of rst person in, namely normal authencaon.
Note
You can authencate by the rst person again to disable the rst person mode.
4.
Click Add on the First Person List panel.
5.
Select person(s) in the le list and the person(s) will be add to the selected persons as the rst
person(s) of the doors.
The added rst person(s) will list in the First Person List
6.
Oponal: Select a rst person from the list and click Delete to remove the person from the rst
person list.
7.
Click Save.
9.7.8
Congure An-Passback
The an-passback feature is designed to minimizes the misuse or fraudulent use of access
credenals such as passing back card to an unauthorized person, or tailed access. The an-
passback
funcon establishes a specic sequence in which access credenals must be used in
order to grant access. You can set the sequence according to the actual path via the client and if
the person uses the
credenal in wrong sequence, you can also reset the an-password records.
Before You Start
Add access control device to the client, and enable the an-passing back funcon of the access
control device.
Steps
Note
Either the an-passing back or mul-door interlocking funcon can be congured for an access
control device at the same me. For the conguraon of mul-door interlocking, refer to .
1.
Click Access Control → Advanced Funcon → An-Passback to enter the An-Passpack Sengs
page.
2.
Select an access control device on the le panel.
3.
Select a card reader as the beginning of the path in the First Card Reader
eld.
DS-K1T341C Series Face Recognion Terminal User Manual
171