Excel 800 LION
EN1B-0375GE51 R0308
58
Terminals
Actuator 2 Actuator 3
31 41 51 61
32
42
52 62
33 43 53 63
34 44 54 64
NO
NC
COM
CON
NO
NC
COM
CON
11
12
13
14
21
22
23
24
25
NO
NC
COM
CON
NO
NC
COM
CON
NO
NC
COM
CON
NO
NC
COM
CON
74
78
73 77
72 76
71 75
24
V~
24
V~
24
V~0
24
V~0
COM
B
COM
B
COM
A
COM
A
Cross connector (can be removed, as desired)
Actuator 1
Fig. 79 Terminal assignment and internal connections of
floating output module
Ter-
minal
Signal Comment
71, 75
COM a
2-wire communication bus (LON/Panel Bus)
72, 76
COM b
2-wire communication bus (LON/Panel Bus)
73, 77
24 V~
Power supply
74, 78
24 V~0
Power supply
11
REL1 N.O.
Floating relay 1 N.O. contact
12
REL1 N.C.
Floating relay 1 N.C. contact
13
R1 COM
Floating relay 1 common contact
14
R1 COM
For connection of floating relay 1 common
via cross connector*
21
REL2 N.O.
Floating relay 2 N.O. contact
22
REL2 N.C.
Floating relay 2 N.C. contact
23
R2 COM
Floating relay 2 common contact
ACTUATOR 1
24
R2 COM
For connection of floating relay 2 common
via cross connector*
31
REL3 N.O.
Floating relay 3 N.O. contact
32
REL3 N.C.
Floating relay 3 N.C. contact
33
R3 COM
Floating relay 3 common contact
34
R3 COM
For connection of floating relay 3 common
via cross connector*
41
REL4 N.O.
Floating relay 4 N.O. contact
42
REL4 N.C.
Floating relay 4 N.C. contact
43
R4 COM
Floating relay 4 common contact
ACTUATOR 2
44
R4 COM
For connection of floating relay 4 common
via cross connector*
51
REL5 N.O.
Floating relay 5 N.O. contact
52
REL5 N.C.
Floating relay 5 N.C. contact
53
R5 COM
Floating relay 5 common contact
54
R5 COM
For connection of floating relay 5 common
via cross connector*
61
REL6 N.O.
Floating relay 6 N.O. contact
62
REL6 N.C.
Floating relay 6 N.C. contact
63
R6 COM
Floating relay 6 common contact
ACTUATOR 3
64
R6 COM
For connection of floating relay 6 common
via cross connector*
25
Shield connection (functional earth),
internally connected to the DIN rail
* Do not connect by wire!
Table 57 Description of floating output module terminals
Manual Overrides
The floating output module is equipped with manual
overrides: one rotary knob for each floating output.
These manual overrides can manually be set to either
"Auto" or "0 … 100 %" (infinitely adjustable).
1 2 3
Honeywell
AUTO
0
!
A A A
100
Fig. 80 Manual overrides (rotary knobs)
NOTICE
Damage to the electronic module!
Do not use a tool to adjust the rotary knobs.
Do not use excessive force. Adjust only by hand.
Auto
In this setting, the signal provided by the respective floating
output (R1 + R2 or R3 + R4 or R5 + R6) and the condition
(ON/OFF) of the respective pair of status LEDs both follow
the commanded output signal.
Override (0…100 %)
When a manual override is set to values in the range of
"0…100 %", the respective floating output will drive to the
set position. The runtime depends upon the actuator runtime
configured in CARE an on the actual position.
Status LEDs
The respective pair of status LEDs will display the following:
Actuator 1
Mode LED
Closing
Opening
Not
moving
Green LED ON OFF OFF
Auto
Red LED OFF ON OFF
Green LED Flashing
OFF Flashing
Override
Red LED OFF Flashing Flashing
Table 58 LED behavior (for e.g., floating output 1)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Excel 800 LION and is the answer not in the manual?

Honeywell Excel 800 LION Specifications

General IconGeneral
BrandHoneywell
ModelExcel 800 LION
CategoryControl Systems
LanguageEnglish