LYNX Touch Installation and Setup Guide
- 40 -
Programming the Control
System Settings
The following system options are programmed in this section:
Option Function
Entry Delay1/Entry Delay 2 Selects an Entry Delay time in seconds. The system will wait the time entered before
sounding alarm upon entering if system is not disarmed.
Note: The Default values differ for the LYNX Touch and LYNX Touch SIA controls.
Exit Delay Selects an Exit Delay time in seconds for both Entry Delay 1 and 2 Zone Types. The
system will wait the time entered before sounding an alarm if the exit door is left open after
the system has been armed.
Note: The Default values differ for the LYNX Touch and LYNX Touch SIA controls.
Backlight Timeout Enable or disable display backlight turnoff after 30 seconds.
Quick Arm Enables or disables Quick Arm Mode. If enabled, security code is not required to arm the
system. The user simply presses the AWAY button (ICON) and then selects the “Quick
Arm” button on the displayed keypad to arm the system.
Quick Exit Enables or disables Quick Exit Mode. If enabled allows the user restart the exit delay to
allow entry or exit when the system is armed
Restart Exit Time Enables or disables Restart Exit Time Mode. This option allows the control to restart the
exit delay time after arming in STAY mode by entering the User Code and pressing the
STAY key (if quick arming is disabled) or by pressing the STAY key (if quick arming is
enabled). This option also enables automatic exit delay reset, which resets exit delay if the
entry/exit door is re-opened and closed before exit delay time expires after arming.
Force Bypass Enables or disables Force Bypass Mode. All zones bypassed by this function will be
displayed after the bypass is initiated. The Fire and CO Zones are not bypassed in the
LYNX Touch.
Exit Warning Enables or disables Exit Warning sound. Audible Exit Warning sound consists of slow
continuous beeps until last 10 seconds, when it changes to fast beeps. The warning sound
will end at the termination of exit delay.
Note: This field is not programmable in the LYNX Touch SIA and is always enabled.
Auto Stay Arming Enables or disables Auto Stay Arming Mode. If this feature is enabled and the control panel
has been armed “Armed Away” at the LYNX Touch keypad or RF keypad, the system will
switch to the “Armed Stay” mode if the Exit Time has expired and no exit has been made.
Lack of Usage Notify Enables or disables Lack of Usage Notification feature. If enabled, notifies the central
station if an end user is not operating their security system by sending a System Inactivity
report 654. The report will be sent only to the Primary phone number and only if Contact
ID® format was selected.
Power-Up in Previous Enables or disables Power-Up in Previous Mode feature. When the system powers up
armed, an alarm will occur 1 minute after arming if a zone is faulted. For the LYNX Touch
control any bypassed zones will be unbypassed. For the LYNX Touch SIA any bypassed
zones will remain bypassed.
Display Alarm Cancel Enables or disables display of Cancelled Alarm.
Display Exit Time Enables or disables display of Exit Time.
Cross Zone Delay Sets the maximum amount of time in which two zones must be tripped in an armed system
to send an alarm message to the Central Station. If only one cross zone is tripped during
this time, a trouble message (CID code 380) for that zone is sent to the Central Station.
Cross Zone 1/Cross Zone 2 Select the zones that will be used for Cross Zoning

Table of Contents

Other manuals for Honeywell LYNX Touch Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell LYNX Touch Series and is the answer not in the manual?

Honeywell LYNX Touch Series Specifications

General IconGeneral
BrandHoneywell
ModelLYNX Touch Series
CategorySecurity System
LanguageEnglish

Related product manuals