Action
Disable automatic collecting of data for the disaster recovery method that failed. This
will allow Data Protector to collect data needed for other methods.
Set the variable OB2_TURNOFF_COLLECTING to one of the following values:
0 Default setting, data collection is turned on for all automatic methods (EADR, OBDR,
ASR).
1 Turn off collecting of EADR/OBDR data. ASR data is still collected.
2 Turn off collecting of ASR data. EADR/OBDR data is still collected.
3 Turn off collecting for all methods.
See “Setting omnirc options during disaster recovery on Windows” on page 136.
Assisted manual disaster recovery
Problem
Drstart reports: “Can not copy ”
This error is reported because the drstart utility can not copy the specified file.
One of the reasons may be that the file is locked by the system. For example, if
drstart cannot copy omniinet.exe, it might be because the Inet service is
already running. This is not a normal scenario and should not happen after a clean
install.
Action
A dialog box will appear asking you whether you would like to proceed with copying
the rest of the files. If you click Yes, drstart will skip the locked file and continue
copying other files. This will solve the problem if the file is locked by the system, as
the process required for the disaster recovery is already running and therefore the
file does not need to be copied.
You can also close the drstart utility by clicking the Abort button.
Troubleshooting disaster recovery140