Removal and Replacement Procedures
2-44 HP ProLiant DL360 Generation 3 Server Maintenance and Service Guide
IMPORTANT: The server serial number must be re-entered through RBSU
after replacing the system
board. Refer to the “Re-entering the Server Serial Number” section.
Re-entering the Server Serial Number
After replacing the server I/O module or clearing the NVRAM, the server serial number must
be re-entered. To re-enter the serial number:
1. During the server startup sequence, press the F9 key to access RBS
U.
2. Select the System Options menu.
3. Select Serial Number. The following wa
rning is displayed:
WARNING! WARNING! WARNING! The serial number is loaded into the
system during the manufacturing process and should NOT be
modified. This option should ONLY be used by qualified service
personnel. This value should always match the serial number
sticker located on the chassis.
Press the Enter key to clear the warning.
4. Enter the serial number and press the Enter key.
5. Press the Escape key to close the menu.
6. Press
the Escape key to exit RBSU.
7. Press the F10 key to confirm exiting RBSU. The server will automatically reboot.