140
Configuring Switch D
Configure Switch D in a similar way Switch C is configured, with the following differences:
• The aggregate interface configured on Switch C is Layer 2 aggregate interface 1.
• The aggregate interface configured on Switch D is Layer 2 aggregate interface 2.
Verifying the configuration
Verifying the configuration on Switch A and Switch B
Verify the configuration on Switch A and Switch B, for example, Switch A.
# Display the domain information of VSAN 100.
[SwitchA] display fc domain vsan 100
Domain Information of VSAN 100:
Running time information:
State: Stable
Switch WWN: 48:33:43:2d:46:43:1A:1A
Fabric name: 48:33:43:2d:46:43:1C:1C
Priority: 128
Domain ID: 2
Configuration information:
Domain configure: Enabled
Domain auto-reconfigure: Disabled
Fabric name: 48:33:43:2d:46:43:1A:1A
Priority: 128
Domain ID: 2 (preferred)
Principal switch running time information:
Priority: 1
Path Interface
Upstream Vfc10
The output shows that the domain configuration is complete on Switch A, and the principal switch assigns
domain ID 2 to Switch A.
# Display the domain ID list of VSAN 100.
[SwitchA] display fc domain-list vsan 100
Domain list of VSAN 100:
Number of domains: 2
Domain ID WWN
0x01(1) 48:33:43:2d:46:43:1C:1C [Principal]
0x02(2) 48:33:43:2d:46:43:1A:1A [Local]
The output shows that Switch C is selected as the principal switch, and the principal switch assigns
domain ID 1 to itself.
# Display the routing table information.
[SwitchA] display fc routing-table vsan 100
Routing Table: VSAN 100