Fabric OS Administrator’s Guide 355
53-1002745-02
Traffic Isolation Zoning over FC routers
12
TI zones within a backbone fabric
A TI zone within a backbone fabric is used to route traffic within the backbone fabric through a
particular ISL. For example, in Figure 40, a TI zone is set up in the backbone fabric to ensure that
traffic between EX_Ports “1,1” and “2,1” is routed through VE_Ports “1,4” and “2,7”.
FIGURE 40 TI zone in a backbone fabric
TI zones within the backbone fabric use the port WWN instead of D,I notation for devices that are to
communicate across fabrics. (You can use the portShow command to obtain the port WWN.)
Port WWNs should be used only in TI zones within a backbone fabric and should not be used in
other TI zones.
Using D,I and port WWN notation, the members of the TI zone in Figure 40 are:
1,1 (EX_Port for FC router 1)
1,4 (VE_Port for FC router 1)
2,7 (VE_Port for FC router 2)
2,1 (EX_Port for FC router 2)
10:00:00:00:00:01:00:00 (Port WWN for the host)
10:00:00:00:00:02:00:00 (Port WWN for target 1)
10:00:00:00:00:03:00:00 (Port WWN for target 2)
Host
Target 1
Target 2
Target 3
FC router 1
Backbone fabric
Edge fabric 1
Edge fabric 2
Edge fabric 3
VE_Ports
1
2
3
4
5
6
1
2
3
7
8
9
= Dedicated Path
= Ports in the TI zone
FC router 2
WWN
WWN
WWN

Table of Contents

Other manuals for HP StoreFabric SN6500B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StoreFabric SN6500B and is the answer not in the manual?

HP StoreFabric SN6500B Specifications

General IconGeneral
BrandHP
ModelStoreFabric SN6500B
CategorySoftware
LanguageEnglish

Related product manuals