Fabric OS Administrator’s Guide 545
53-1002745-02
F_Port trunking
22
Use the following procedure on the edge switch connected to the Access Gateway module to
configure F_Port trunking.
1. Connect to the switch and log in using an account assigned to the admin role.
2. Enter the portCfgShow command to ensure that the ports have trunking enabled. If trunking is
not enabled, enter the portCfgTrunkPort port 1 command.
3. Enter the portDisable command for each port to be included in the TA.
4. Enter the portTrunkArea
--enable command to enable the trunk area.
For example, the following command creates a TA for ports 36–39 with index number 37.
switch:admin> porttrunkarea --enable 36-39 -index 37
Trunk index 37 enabled for ports 36, 37, 38 and 39.
When you assign a trunk area on a port, it enables trunking on the F_Ports automatically. This
command does not unassign a TA if its previously assigned Area_ID is the same Address
Identifier (Area_ID) of the TA unless all the ports in the trunk group are specified to be
unassigned.
5. Enter the portEnable command to reenable the ports in the TA.
F_Port trunking for Brocade adapters
You can configure trunking between the F_Ports on an edge switch and the Brocade adapters.
In addition to the requirements listed in “Requirements for trunk groups” on page 536, note the
following requirements, which are specific to F_Port trunking for Brocade adapters:
The edge switch must be running in Native mode. You cannot configure trunking between the
Brocade adapters and the F_Ports of an Access Gateway module.
You can configure only two F_Ports in one trunk group.
See the Brocade Adapters Administrator’s Guide for information about configuring the
corresponding N_Port trunking on the Access Gateway and the Brocade adapter.
Configuring F_Port trunking for a Brocade adapter
F_Port trunking for Brocade adapters requires configuration on the FC switch as well as on the
Brocade HBAs. This section describes the configuration steps you do on the switch. See the
Brocade Adapters Administrator’s Guide for a detailed description and requirements of N_Port
trunking on the adapters.
1. On the switch side, perform the following steps:
a. Configure both ports for trunking by using the portCfgTrunkPort command.
switch:admin> portcfgtrunkport 3/40 1
switch:admin> portcfgtrunkport 3/41 1
b. Disable the ports to be used for trunking by using the portDisable command.
switch:admin> portdisable 3/40
switch:admin> portdisable 3/41

Table of Contents

Other manuals for HP StoreFabric SN6500B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StoreFabric SN6500B and is the answer not in the manual?

HP StoreFabric SN6500B Specifications

General IconGeneral
BrandHP
ModelStoreFabric SN6500B
CategorySoftware
LanguageEnglish

Related product manuals