EasyManuals Logo
Home>HP>Software>StoreFabric SN6500B

HP StoreFabric SN6500B User Manual

HP StoreFabric SN6500B
666 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #382 background imageLoading...
Page #382 background image
382 Fabric OS Administrator’s Guide
53-1002745-02
Setting bottleneck detection alerts
13
Switch-wide sub-second latency bottleneck criterion:
====================================================
Time threshold - 0.800
Severity threshold - 50.000
Switch-wide alerting parameters:
============================
Alerts - Yes
Latency threshold for alert - 0.100
Congestion threshold for alert - 0.800
Averaging time for alert - 300 seconds
Quiet time for alert - 300 seconds
Example of status output showing that only a congestion alert at the switch level has been set
switch:admin> bottleneckmon --status
Bottleneck detection - Enabled
==============================
Switch-wide sub-second latency bottleneck criterion:
====================================================
Time threshold - 0.800
Severity threshold - 50.000
Switch-wide alerting parameters:
============================
Alerts - Congestion only
Congestion threshold for alert - 0.800
Averaging time for alert - 300 seconds
Quiet time for alert - 300 seconds
Per-port overrides for alert parameters:
========================================
Port Alerts? LatencyThresh CongestionThresh Time (s) QTime(s)
================================================================================
1 Y 0.100 0.800 300 300
2 C -- 0.800 600 600
3 L 0.100 -- 300 300
4N-- -- -- --
NOTE
If there are no per-port overrides, then that section is not displayed.
Setting bottleneck detection alerts
You can configure Fabric OS to log per-port alerts based on the latency and congestion history of
the port. Alerts are generated based on the number of affected seconds over a specified period of
time. If the number of affected seconds is higher than the threshold, an alert is generated.
This evaluation is done independently for latency and congestion.
The bottleneckmon -alert parameters described below determine whether an alert is generated
and what for.
For example, Figure 48 shows an interval of 12 seconds, in which 6 seconds are affected by a
congestion bottleneck and 3 seconds are affected by a latency bottleneck.

Table of Contents

Other manuals for HP StoreFabric SN6500B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StoreFabric SN6500B and is the answer not in the manual?

HP StoreFabric SN6500B Specifications

General IconGeneral
BrandHP
ModelStoreFabric SN6500B
CategorySoftware
LanguageEnglish

Related product manuals