For details, see FusionServer Pro Rack Server Upgrade Guide.
Step 4 Query health status.
1. On the menu bar, choose Information.
2. In the navigation tree, choose Overview to query the health status.
Figure 7-31 Querying health status
Step 5 Query alarm information.
Check whether any alarm is generated.
If yes, handle the alarms.
For details, see FusionServer Pro Rack Server iBMC Alarm Handling.
If no, no further action is required.
----End
7.4.5 Setting the iBMC IP Address
Scenarios
This section describes how to set the iBMC IP address on the BIOS.
You can set the iBMC IP address on:
BIOS
iBMC WebUI
For details, see FusionServer Pro Rack Server iBMC User Guide.
iBMC CLI
Run the following command: ipmcset -d ipaddr
For details, see FusionServer Pro Rack Server iBMC User Guide.
Default IP Address
Default IP Address
Default Subnet Mask
192.168.2.100 255.255.255.0
FusionServer Pro 1288H V5 Server
User Guide 7 Installation and Conguration
Issue 13 (2020-06-05) Copyright © Huawei Technologies Co., Ltd. 92

Table of Contents

Other manuals for Huawei FusionServer Pro 1288H V5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei FusionServer Pro 1288H V5 and is the answer not in the manual?

Huawei FusionServer Pro 1288H V5 Specifications

General IconGeneral
ProcessorIntel Xeon Scalable processors
MemoryUp to 3 TB
Memory Slots24 DDR4 DIMM slots
StorageSupports up to 10 x 2.5-inch SAS/SATA/SSD drives or 4 x 3.5-inch SAS/SATA drives
RAID SupportRAID 0, 1, 10, 5, 50, 6, 60
Network2 x GE + 2 x 10GE ports
Power Supply1+1 redundant, hot-swappable PSUs
Form Factor1U rack