Chip Model Port Type Rate
Negotiation
Mode
Supported
Rate
Rates Not
Supported
Auto-
negotiation
10000 Mbit/s
(full duplex)
10000M 10/100M
GE electrical
port
Auto-
negotiation
1000 Mbit/s
(full duplex)
1000M 10/100M
● Use Intelligent Computing Compatibility Checker to obtain information
about the cables and optical modules supported by the LOM ports.
● The LOM ports support NC-SI, WOL, and PXE.
● The LOM ports do not support forced rates.
● The electrical LOM ports cannot be connected to power over Ethernet (PoE)
devices (such as a switch with PoE enabled). Connecting a LOM port to a PoE
device may cause link communication failure or even damage the NIC.
● The electrical LOM ports do not support SR-IOV.
● Forcibly powering
o a server will cause intermittent NC-SI disconnection
and disable the Wake on LAN (WOL) function of the LOM ports. To restore
the NC-SI connection, refresh the iBMC WebUI.
2.3 Processor
● The server supports one or two processors.
● If only one processor is required, install it in socket CPU1.
● The same model of processors must be used in a server.
● Contact your local Huawei sales representative or use the Intelligent
Computing Compatibility Checker to determine the components to be used.
FusionServer Pro 1288H V5 Server
User Guide 2 Hardware Description
Issue 13 (2020-06-05) Copyright © Huawei Technologies Co., Ltd. 17