Troubleshooting
Echion Operator Manual 810770 11 5
Warnings
Alarm Cause Solution
Warning: Battery Error The controller battery is not
operating correctly.
Contact a Hypertherm Technical
Service Associate for information
and support.
Warning: Boost Motor
Warning: Fan Motor
The boost motor or the fan motor
did not start because the thermal
overload relay has tripped.
Reset the relay.
• Find the thermal overload relay
on the motor starter.
• Turn the knob clockwise to the
ON position (I).
• Release the knob. It snaps
counterclockwise to the
OFF
position (O).
• Turn the knob clockwise to the
ON position (I) again.
On Tripped Off
Warning: Start Procedure
Hydraulics
An error occurred during stage3 of
the start sequence.
• The cutting head is on.
• The bleed-down valve is
leaking.
• The bleed-down valve is not
receiving air.
• The Hydraulics timer setting is
too short.
• Make sure that the cutting head
is off.
• Repair or replace the
bleed-down valve.
• Make sure that the compressed
air supply is on.
• Adjust the timer on the
Start-procedure Timers screen.
Refer to Start Procedure
Timers on page 166
Warning: Start Procedure Ramp
to Pierce Pressure
An error occurred during stage4 of
the start sequence.
Warning: Start Procedure Ramp
to Cut Pressure
An error occurred during stage5 of
the start sequence.
Warning: Too Many Motor Starts
in15 Minutes
Starting and stopping the motor
rapidly can cause damage to the
motor.
Wait longer between stopping and
starting the motor.