Troubleshooting
5
116 810770 Operator Manual Echion
Troubleshooting
Faults
Fault conditions cause the pump to turn off.
Alarm Cause Solution
Fault 1: Hydraulic Fluid>65C
The hydraulic fluid temperature is
higher than65ºC(149ºF).
The system is not cooling
sufficiently.
Refer to Temperature on page 124.
Fault 1: Intensifier Overstroke to
Left
Fault 1: Intensifier Overstroke to
Right
An overstroke fault occurs when the
hydraulic piston travels faster than
the pump can sustain.
A poppet (high-pressure or
low-pressure) is stuck or is leaking.
Check the low-pressure poppet on
the same side as the overstroke.
Check the high-pressure poppet on
the opposite end from the
overstroke.
Refer to Overstroke on page 121.
Fault 1: Low Inlet Water Pressure The supply-water pressure is lower
than2.8bar(280kPa/40psi).
Increase the supply pressure.
Pressure is lost because of a leak. Identify the source of a leak and
correct the problem.
The supply water is off. Turn ON the supply water.
Fault 2: Hydraulic Fluid45C
Sensor
The temperature sensor in the
hydraulic fluid tank has failed.
Replace the sensor.
Fault 2: Hydraulic Fluid Level is
Low
The float switch in the hydraulic
fluid tank monitors the fluid level.
A hydraulic fitting or a hydraulic
hose is leaking.
Fix the leak.
Refer to Hydraulic fluid on
page 123.
The sensor is faulty. If the tank is full, replace the sensor.
A poppet (high-pressure or
low-pressure) is stuck or leaking.
Check the low-pressure poppet.
Fault 2: Input to Primary Motor
Not Received
The controller did not receive a
signal from the starter when the
pump was turned on.
Contact a Hypertherm Technical
Service Associate for information
and support.
Fault 2: Water Pressure Control
Error
The pump did not get to the target
water pressure within the expected
time.
The hydraulic pressure
transducer on the pump
manifold has failed.
The proportional valve has
failed.
The proportional valve coil has
failed.
The hydraulic pump has failed.
Replace the component.
The orifice has failed. Check the condition of the orifice.
Replace it, if necessary.
A component inside the hydraulic
center section has failed.
Contact a Hypertherm Technical
Service Associate for information
and support.