Table 20. Control enclosure battery LEDs (continued)
Battery Good
+
-
Battery Fault
+
-
Description Action
Off On Nonrecoverable battery fault. Replace the battery. If
replacing the battery
does not fix the issue,
replace the power supply
unit.
Off Flashing Recoverable battery fault. None
Flashing Flashing The battery cannot be used
because the firmware for the
power supply unit is being
downloaded.
None
Management GUI interface
The management GUI is a browser-based GUI for configuring and managing all
aspects of your system. It provides extensive facilities to help troubleshoot and
correct problems.
You use the management GUI to manage and service your system. The Monitoring
> Events panel provides access to problems that must be fixed and maintenance
procedures that step you through the process of correcting the problem.
Two tabs are available for monitoring events:
v A Block tab for monitoring the SAN volume events and the file system volume
events from the control enclosure.
v A File tab for monitoring the NAS events from the Storwize V7000 file modules.
When you click the Block tab, a Next recommended action is shown. Perform the
next recommended action before attempting any other recommended actions.
The information on the Events panel can be filtered three ways:
Recommended actions (default)
Shows only the alerts that require attention. Alerts are listed in priority
order and should be fixed sequentially by using the available fix
procedures. For each problem that is selected, you can:
v Run a fix procedure.
v View the properties.
Unfixed messages and alerts
Displays only the alerts and messages that are not fixed. For each entry
that is selected, you can:
v Run a fix procedure.
v Mark an event as fixed.
v Filter the entries to show them by specific minutes, hours, or dates.
v Reset the date filter.
v View the properties.
Show all
Displays all event types whether they are fixed or unfixed. For each entry
that is selected, you can:
Chapter 3. Getting started troubleshooting 47
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 2076-324 and is the answer not in the manual?

IBM Storwize V7000 2076-324 Specifications

General IconGeneral
BrandIBM
ModelStorwize V7000 2076-324
CategoryStorage
LanguageEnglish

Related product manuals