Draco tera
238 2020-02-26
Maximum Acceptable Cable Length
Cat X Installation Cable
AWG24
Cat X Patch Cable
AWG26/8
Pos: 154 /806-IHS E/Technisch e Daten/Verbi ndungskabel/480-x x/Glasfaser @ 7\mod_130 9942335305_6. doc @ 53729 @ 3 @ 4
7.2.2 Fiber
A point-to-point connection is necessary. Operation with multiple patch
panels is allowed. Routing over active network components, such as
Ethernet Hubs, Matrixes or Routers, is not allowed.
Type of Interconnect Cable
(Cable notations according to VDE)
Two fibers 9μm
I-V(ZN)H 2E9 (in-house patch cable)
I-V(ZN)HH 2E9 (in-house breakout
cable)
I/AD(ZN)H 4E9 (in-house or outdoor
breakout cable, resistant)
A/DQ(ZN)B2Y 4G9 (outdoor cable, with
protection against rodents)
Two fibers 50μm
I-V(ZN)H 2G50 (in-house patch cable)
I/AD(ZN)H 4G50 (in-house or outdoor
breakout cable, resistant)
Two fibers 62,5μm
I-V(ZN)HH 2G62,5 (in-house breakout
cable)
A/DQ(ZN)B2Y 4G62,5 (outdoor cable,
with protection against rodents)
Only use Single-mode connection cables for fiber connections that are
based on 3G SFPs.