Troubleshooting
2020-02-26 251
9.4 Malfunction of Power Supply Units
Diagnosis
Possible Reason
Measure
Matrix cannot
be started
Power supply units not
locked correctly
Check lock and plug-in of the
power supply units.
No power supply
available
Check if power supply cables are
connected correctly.
Power supply units are
not switched on
Check switch on the power
supply units.
Pos: 186 /806-IHS E/Hilfe im Pro blemfall/Netzw erkstörung/480- xx @ 7\m od_1309944607415 _6.doc @ 541 33 @ 2 @ 1
9.5 Network Error
Diagnosis
Possible Reason
Measure
Network
settings are not
assumed after
editing.
Restart of the matrix not
yet completed.
Restart the matrix.
188 /806-IHSE/Hilf e im Problemfall/ Störung an der Matrix/480- xx @ 7\mod _130994433138 3_6.doc @ 540 40 @ 2 @ 1
9.6 Failure at the Matrix
Diagnosis
Possible Reason
Measure
Serial control
impossible or
only restrictedly
possible.
CPU and matrix
operating at different
Baud rates.
Change Baud rate in the matrix
and CPU (see Chapter 5.3.2,
Page 80).
Serial control via
RJ45 port not
possible.
Wrong network cable.
Use a crossed network cable.
Port definitions
as USB 2.0
invalid.
Restart of the matrix not
yet completed.
Restart the matrix.
Pos: 189 /806-IHS E/zz_Layout/ Seitenumbruch @ 8\mod_134 8581820516_ 0.doc @ 69462 @ @ 1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ihse K480-288 and is the answer not in the manual?

Ihse K480-288 Specifications

General IconGeneral
BrandIhse
ModelK480-288
CategorySwitch
LanguageEnglish

Related product manuals