Technical Specification
The above specifications may be subject to change without prior notice.
1. Internal absorption current and internal absorption power mean the
absorption current and power of the standard load inside the power supply.
2. Resistance programming accuracy differs based on different output current.
For example, 10A Transient 1.0Ω, accuracy: (1.0Ω* 0.25%) +(30mΩ*A /10A) =
5.5mΩ
3. Set value accuracy means the set accuracy realized through the panel button
or communication instructions. When external analog is used for programming,
the programming accuracy is 2%FS.
4. Read-back value accuracy means the read-back accuracy realized through
panel display or communication instructions; when external analog is used for
monitoring, the monitoring accuracy is 1%FS.
5. Up time and down time mean the time of establishment from one value to
another value under ON status when the internal standard power dissipater is
enabled.
6. Use 12V/120AH battery for test.
7. When used in parallel, to balance power of each phase, distribute the
instrument to three phases. But must ensure that single machine input voltage
meets Specification requirements.
8. It means the maximum phase current value under minimum work input
voltage.
5.1.3 IT6532C
Parameter IT6532C Ver:V1.6
Output Rating ( 0 ℃-40 ℃)
Output Voltage
0~80V
Output Current
0~240A
Internal Sink
Current
1
0~100A
Output Power
0~6KW
Internal Sink
Power
1
0~300W
Output Resistance
Range
0~1.067Ω
Accuracy
2
0.25%+30mΩ*A
Resolution 0.1mΩ
Line regulation
±(%of Output+Offset)
Voltage
≤0.01%+10mV
Current ≤0.01%+120mA
Copyright © Itech Electronic Co., Ltd.
98