Function and Features
Call the self-defined DIN waveform operation (taking 12.5V voltage
waveform as an example):
1. Press [Shift]+ [I-set](Function) to enter the Menu operation.
2. Select Road-Vehicle with Left/Right key and press [Enter] for
confirmation.
3. Select DIN40839 with Left/Right key and press [Enter] for confirmation.
4. Select On with Left/Right key and press [Enter] for confirmation.
5. Press Left/Right key to select User-defined. Press [Enter] for
confirmation.
6. Set the startup voltage value, V=12.6V. Press [Enter] for confirmation.
7. DIN40839 appears at the right bottom of the panel.
8. Press [On/Off] to turn on power supply output.
9. Press [Shift]+[Enter](Trigger) for trigger. The power supply will output
based on set sequence. Trig mark is lit.
3.20.2 simulate the waveform to verify the anti-
interference performance of the automotive electronics’
products
IT6500C models have built-in ISO16750-2 waveforms. To verify the anti-
interference performance of the automotive electronics’ products. Output pulse
waveform completely meets the International Standard ISO-16750-2,
convenient for quick recall by the user.
Copyright © Itech Electronic Co., Ltd.
57

Table of Contents

Other manuals for ITech IT6500C Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6500C Series and is the answer not in the manual?

ITech IT6500C Series Specifications

General IconGeneral
BrandITech
ModelIT6500C Series
CategoryPower Supply
LanguageEnglish

Related product manuals