Function and Features
5. Connect the networking as shown above. Please connect the network after
parallel setup. Otherwise, at start up, the power supply will detect parallel
setup fault and fail to start up.
To change Parallel Mode to Single Mode, follow the steps below:
1. Power off the power supplies.
2. Remove System Bus among the power supplies.
3. Install the terminal matching resistance on the device which is uninstalled.
Insert it to the Input or Output of the System Bus interface.
4. Restart the power supply and enter to “NETWORKING…” status.
5. Press [shift]+[Esc], clear the error status and set the master mode or slave
mode to single mode.
6. Repeat steps 3 through 4 for each device under parallel mode to change all
devices to single operation mode.
3.23 Analogue Interface (Enhanced Isolation)
A DB25 analog interface is set at the rear panel of the power supply, through
which, you can connect the external voltage (0V-5V/0V-10V) or external
resistance (0KΩ-5KΩ/0KΩ-10KΩ) to program output voltage or current on 0-full
range. At the same time, with analog monitoring function (0V-5V/0V-10V), you
can monitor the output voltage or current on 0-full range.
Analog signal bandwidth is less than 100Hz,. support any waveform within
signal bandwidth. When the program signal frequency or amplitude exceeds
output capacity, the output amplitude will be automatically limited.
In parallel operation, you can program or monitor output through the host
analog interface. The 0V-5V/0V-10V program and monitoring range is changed
to 0-full range of parallel machine. Safe electrical isolation is set between this
analog interface and output electrode.
To run this function, you need to set the parameters below:
Monitor 10V(Def) 10V monitoring mode options
5V 5V monitoring mode options
Ext- Ctrl External control mode and related parameter setting
Voltage(Def) Voltage setting mode selection
10V(Def)/5V 10V or 5V setting mode selection,
select by Left/Right key.
Copyright © Itech Electronic Co., Ltd.
75

Table of Contents

Other manuals for ITech IT6500C Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6500C Series and is the answer not in the manual?

ITech IT6500C Series Specifications

General IconGeneral
BrandITech
ModelIT6500C Series
CategoryPower Supply
LanguageEnglish

Related product manuals