display. When enabled, if the power supply output state is ON (enabled) and if
the display shows setting voltage and current, it will automatically switch to
measured voltage and current display after 5 seconds.
1. Press composite keys [Shift]+[P-set](Menu) enter to system menu.
2. Select SYSTEM, press [Enter] to confirm.
3. Select ReturnMeter with Left/Right key and press [Enter] to confirm.
4. Select On or Offwith Left/Right key and press [Enter] to confirm.
3.9.7 Power On Output State (P-OUT)
This item can set the power on output state. If you select Last item, that
indicates the power on output state is the same with output state before this
item is set. If you select Off item, unit will automatically in off mode when you
power on. Factory default is Off option. And this setting is effected by Power-on,
and take effect when the Power-on set to Save0.
1. Press composite keys [Shift]+[P-set](Menu) enter to system menu.
2. Select SYSTEM, press [Enter] to confirm.
3. Select P-Out with Left/Right key and press [Enter] to confirm.
4. Select Last or Offwith Left/Right key and press [Enter] to confirm.
3.9.8 Load Setup Option (Load)
The power supply has an internal dummy load that can be enabled to increase
the speed of the voltage fall time for high speed test applications. Default setting
is Off status.
Internal load
When the load function is initiated, the system is defaulted to be in internal load
mode. By default, the default value of power is power rated values. The default
value of current is small and different for each model. Please refer to the actual
value.
The user can turn on load function in the Configuration Menu. Detailed
operations are as follows.
1. Press [Shift]+ [P-set](Menu) to enter the Menu operation.
2. Press the Right key to select CONFIG in the Menu to enter the Menu
operation and select Load-Status. Press [OK]/[Enter] for confirmation and
select the Load to set the load status.
3. The user can select On through Arrow key to turn on the load function.
Copyright © Itech Electronic Co., Ltd.
30

Table of Contents

Other manuals for ITech IT6500C Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6500C Series and is the answer not in the manual?

ITech IT6500C Series Specifications

General IconGeneral
BrandITech
ModelIT6500C Series
CategoryPower Supply
LanguageEnglish

Related product manuals