5.3 Servicing PzV and PzV-BS lead-acid batteries with sealed armour
plated cells
Z Do not add water!
5.3.1 Daily
Charge the battery after each discharge.
5.3.2 Weekly
Visually inspect for dirt and physical damage.
5.3.3 Every three months
Measure and record the overall voltage.
Measure and record the individual voltages.
Compare the results with the previous ones.
Z Carry out the measurements after full charging and subsequent resting for at least
5 hours.
Z If you find significant differences compared with the previous measurements or
differences between the cells, contact the manufacturer's customer service
department.
5.3.4 Annually
Measure the insulation resistance of the truck in accordance with EN 1175-1.
Measure the insulation resistance of the battery in accordance with DIN EN 1987-1.
Z In accordance with DIN EN 50272-3 the battery insulation resistance should not be
less than 50 Ω per volt of rated voltage.