ThesecondaryLCLlterconnectionsofsize14...24H6aredesignedwith
shielded lines for U, V, W and Fan 1/2 (AWG 16), FT 1/2 (AWG 18). At size
26Z1 there are ring crimp connectors M8 and two terminal blocks (4mm²) for
fan and temperature sensor (KTY +/-) / switch (T1/T2) installed.
At size 29Z1 there are ring crimp connectors M10 (connection PE M12) and
two terminal blocks (4mm²) for fan and temperature sensor (KTY +/-) / switch
(T1/T2) installed.
4.2.2 Common mode lter
Thecommonmodelterreducestheleakagecurrentandtheripplecurrentbycouplingto
theDCbus.Thecommonmodelterconsistsofacompensationchokeandacapacitor
set.
Size Housing Filter combination
fSN
kHz
IN
A
Consisting of
AIC / LCL lters Common mode lter
22 R 22Z1I04-1000 8...16 115 24H6J4F-1001 22Z1H04-1000
26 U – 4...16 250 26Z1K04-1000 26Z1H04-1000
29 P 29Z1I04-1000 4...16 460 29Z1K04-1000 29Z1H04-1000
Table 9: Common mode lter
Sine-waveEMClterswithDCregenerationandmainschokescanbeusedalternatively.
Sine-wave EMC lters
Mains choke
Rated current IN
A
Switching frequency fS
kHz
0DZ1I05-1001 12Z1B04-1000 9.5
8...16
0HZ1I05-1001 14Z1B04-1000 16.5
0LZ1I05-1001 18Z1B04-1000 50
0PZ1I05-1001 22Z1B04-1000 115
0SZ1I05-1001 24Z1B04-1000 180
0XZ1I05-1001 27Z1B04-1000 300
4...16
0YZ1I05-1001 29Z1B04-1000 460
Table 10: Sinus EMC lters and mains chokes
Further information can be found under the following link:
InstallationsinusEMClter.
www.keb.de/leadmin/media/Manuals/dr/ma_dr_z1-inst-sinus-emv-l-
ter_20146892_de.pdf
Programming manual COMBIVERT F5-AIC.
www.keb.de/leadmin/media/Manuals/f5afe/prog/F5_AFE_pro-
gramm_20104270_deu.pdf
31