9.3 Technical data of the COMBIVERT F5 AIC devices
Max. precharging AIC at an ambient temperature Ta = 45°C and UN_max = 440V / 480V.
Corresponding higher charging currents are expected at higher mains voltages. In this
case please contact KEB!
Size S Cint
Cext_max
at
U = 440V / 480V
R
Max. exter-
nal charging
current
at
U = 440V / 480V
Max. total
charging
current
at
U = 440V / 480V
Notes
AIC kVA uF uF A A
14 11 820 20 73 / 67 104 NTC as shunt
16 23 1260 10 130 / 120 190
18 35 1800 20 320 / 315 350
20 52 3900 40.000/35.000 2.5 250/270
22 80 4950 40.000/35.000 2.5 250/270
24 125 8250 35.000/30.000 2.5 250/270
26 173 11700 33.000/27.000 2.5 250/270
27 208 14100 30.000/24.000 2.5 250/270
28 256 19800 27.000/20.000 5.8 - 107/117
1)
29 319 19800 27.000/20.000 5.8 107/117
30 395 39600 140.000/110.000 5.8
1)
- 107/117
1)
33 554 59400 230.000/180.000 3.9
1)
- 161/175
1)
34 616 39600 140.000/110.000 5.8
1)
107/117
1)
38 1005 59400 230.000/180.000 3.9
1)
- 161/175
1)
Legend
S Apparent power
Cint Internal capacity
Cextmax Maximum, connectable capacity
R Load-shunt
Table 20: Technical data of KEB COMBIVERT F5 AIC devices
1)
Option precharging resistor => „Additional precharging resistor at master-slave operation“.
NOTICE
A restart for AIC with NTC is allowed only after 5 minutes.
61
DIMENSIONING

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT 19F5 Series and is the answer not in the manual?

KEB COMBIVERT 19F5 Series Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT 19F5 Series
CategoryInverter
LanguageEnglish

Related product manuals