F-2 Model 2302 Specifics
General information
NOTE Since the Model 2302 and 2302-PJ are single channel battery simulators, functions
contained in this manual related to the second channel (i.e., the charger channel) are
not available for the Model 2302 and 2302-PJ. With this in mind, for the Model 2302
and 2302-PJ, only battery channel features contained in this manual apply.
Specifications
Full power supply specifications can be found in Appendix A of this manual.
Power supply overview
The Model 2302 and 2302-PJ power supplies (single channel battery simulator —
Figure F-1) simulate a battery. The features match the battery
channel features (Channel 1)
documented in this manual (2306-901-01).
Operational differences
Front panel operation
Since the Model 2302 and 2302-PJ are single channel units, disregard any statements in the
manual such as “Toggle active channel using the
s
or
s
keys.” Also, the #1 or #2 indicating the
active channel is not displayed—the active channel is always the battery channel.
SCPI operation
If a channel 2 bus command is issued, an “Undefined header” error (-113) will result.
*IDN? will reflect the Model 2302 and 2302-PJ in
stead of the Model 2306, 2306-VS, or
2306-PJ.
When using the DISP:CHAN command, only send a “1” as a parameter. Other values will
result
in a parameter data out of range error (-222).
The BOTHOUTON and BOTHOUTOFF along with other BOTH commands do not work
with
the Model 2302 or 2302-PJ.
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
TestEquipmentDepot.com