TP-7070 7/1882 Section 3 Scheduled Maintenance
Sampling Methods
Method 1: Sampling with a Syringe
1. Read and follow the safety precautions in
Section 3.1.
2. Connect a flexible hose to the syringe.
3. Insert the other end of the hose into the dipstick
well, taking care not to reach the bottom of the
sump.
4. Draw the oil into the syringe until it is completely
filled..
5. Once the syringe is full, remove the hose, empty
the syringe into the bottle and seal it as soon as
possible.
6. If necessary, repeat the operation until the bottle is
3/4 full.
7. Close the bottle by tightly screwing the cap and
check the information on the label.
Method 2: Sampling at the Drainage Point
This method can be used by adapting the periodic
draining of the oil sump.
1. Read and follow the safety precautions in
Section 3.1.
2. Place a basin under the drain point.
3. Open the drain point.
4. Allow a little oil to flow out before collecting the
sample.
5. Fill the bottle tightly to 3/4 full.
6. Close the bottle by tightly screwing the cap and
check the information on the label.
7. Close the drain point.
8. Top up the engine oil if necessary.
Recommended Tests
The recommended tests for the analysis are shown in
Figure 3-6 and Figure 3-7.
Spectrometric Analysis (wear) Units
Iron (Fe) DIN 51399-1:2012-5 mg/kg
Chromium (Cr) DIN 51399-1:2012-5 mg/kg
Tin (Sn) DIN 51399-1:2012-5 mg/kg
Aluminum (Al) DIN 51399-1:2012-5 mg/kg
Nickel (Ni) DIN 51399-1:2012-5 mg/kg
Copper (Cu) DIN 51399-1:2012-5 mg/kg
Lead (Pb) DIN 51399-1:2012-5 mg/kg
Molybdenum (Mo) DIN 51399-1:2012-5 mg/kg
PQ Index
Impurities
Silicon (Si) DIN 51399-1:2012-5 mg/kg
Potassium (K) DIN 51399-1:2012-5 mg/kg
Sodium (Na) DIN 51399-1:2012-5 mg/kg
Water DIN 51,451 %
Glycol DIN 51375-1 %
Vegetable oil DIN 51639-4:2010-02 %
Diesel fuel DIN 51375-1 %
Biodiesel DIN 51375-1 %
Soot DIN 51452 %
Figure 3-6 Oil Spectrometric Analysis
Physical parameters Units
Viscosity at 40_C DIN 51562 mm
2
/s
Viscosity at 100_C DIN 51562 mm
2
/s
Viscosity Index (VI) calc.
Oxidation DIN 51451, DIN 51453 A/cm
Nitration DIN 51451, DIN 51453 A/cm
Salvation DIN 51451, DIN 51453 A/cm
Dirt moving capability %
TBN (total base number) DIN ISO 3771 mgKOH/g
TAN (total acid number) DIN EN 12634-1999-02 mgKOH/g
pH
Additives
Calcium (Ca) DIN 51399-1:2012-5 mg/kg
Magnesium (Mg) DIN 51399-1:2012-5 mg/kg
Boron (B) DIN 51399-1:2012-5 mg/kg
Zinc (Zn) DIN 51399-1:2012-5 mg/kg
Phosphorous (P) DIN 51399-1:2012-5 mg/kg
Barium (Ba) DIN 51399-1:2012-5 mg/kg
Molybdenum (Mo) DIN 51399-1:2012-5 mg/kg
Sulphur (S) DIN 51399-1:2012-5 mg/kg
Figure 3-7 Oil Physical Parameters

Table of Contents

Other manuals for Kohler KD1750

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler KD1750 and is the answer not in the manual?

Kohler KD1750 Specifications

General IconGeneral
BrandKohler
ModelKD1750
CategoryInverter
LanguageEnglish

Related product manuals