MAINTENANCE
SERVICE PROCEDURE
REPLACE SLOW BLOW FUSE
NOTICE
Always turn the power OFF when replacing the slow blow fuse (turn the
starting switch to the OFF position).
Always replace the slow blow fuse with a fuse of the same capacity.
1. Turn the starting switch to the OFF position.
2.
Remove the slow blow fuse box from the chassis.
3.
Open covers (1), (2), and (3) of the slow blow fuse box.
Covers (2) and (3) can be removed easily by using protrusion
(A) on the body as a fulcrum and levering the catch of the cover
with a flat-headed screwdriver to release it.
4. Loosen screws (4) and (5), and remove.
When screws (4) and (5) are removed, slow blow fuse (6) will
also come off together with electric wiring (7) and (8).
5. Using screws (4) and (5), install a new slow blow fuse together
with electric wiring (7) and (8) to the slow blow fuse box, then
close covers (1), (2), and (3).
6. Install the slow blow fuse box to the chassis.