MAINTENANCE
SERVICE PROCEDURE
CLEAN ELEMENT IN AIR CONDITIONER FRESH AIR FILTER
WARNING
If compressed air scattered around dust and debris, there is danger of injury. Always wear protective equipment such as
protective glasses and mask.
If the air conditioner has been used, the air filter should be cleaned.
Stop the air conditioner before cleaning the element.
1. Loosen bolt (1) and remove cover (2).
2.
Loosen screw (3), then take out element (4) and clean it.
3.
Direct dry compressed air (less than 0.69 MPa (7 kg/ cm
2
, 99.4
PSI)) to the element from inside along its folds, then direct it
from outside along its folds and again from inside.
REMARK
When assembling the element again, install so that the arrow at the
top of the element faces the inside of the cab.