WSM Minor Change II Service Engineering Section
2. LCD display list
Below list shows all LCD letter indications for both oparating mode.
In operating mode, data 003 ~ 022 and 082, 084 will be on the display according to the machine condition.
In case of non AI, non S/P control machines, date 008 ~ 022 except 017, 018, 019, 020, 021 won’t come up
to show.
<Operating mode menu list>
name
English
meaning and explanation
data000
This LCD display shows the following conditions;fuel amount, water temp., engine
oil pressure, battery, glow plug, and operating hour meter.
data001
This LCD display shows the following conditions;fuel amount, water temp., engine
speed.
data002
This LCD display shows the following conditions;fuel amount, water temp.,
and operating hour meter.
data003 The letter on the LCD indicates the warning of each function;fuel amount shortage
data004 The letter on the LCD indicates the warning of low engine oil pressure
data005 The letter on the LCD indicates the warning of low charging voltage of alternator
data006
The letter on the LCD indicates the warning of each function; higher voltage line
connected for example, 24 V battery
data007
The letter on the LCD indicates the warning thepossibility of engine overheating
condition EU - version only : 124 ± °C
data008 The letter on the LCD indicates the warning ofaccel sensor line break or shortage
data009
The letter on the LCD indicates the warning of governor sensor line break or
shortage
data010 The letter on the LCD indicates the warning of AI motor line shortage.
data011 The letter on the LCD indicates the warning of AI motor line break.
data012 The letter on the LCD indicates the amount of auxiliary port flow.
data013
The letter on the LCD indicates the warning of electrical shortage of aux. solenoid
valve left side.
data014
The letter on the LCD indicates the warning of electrical line break of aux. sole-
noid valve left side.
data015
The letter on the LCD indicates the warning of electrical shortage of aux. solenoid
valve right side.
data016
The letter on the LCD indicates the warning of electrical line break of aux. sole-
noid valveright side.
data017
The letter on the LCD indicates the warning of coolant sensor or water temp. sen-
sor fail.
data018 The letter on the LCD indicates the warning of fuel sensor fail.
data019 The letter on the LCD indicates the warning of 12V sensor supply line shortage.
data020 The letter on the LCD indicates the warning of 5V sensor supply line shortage.
data021 The letter on the LCD indicates the warning of controller error in the meter panel.
data022
The letter on the LCD indicates the warning of AI motor being restricted by any
means.
data082 These indicates where machine was manufactured.
data084 This indicates that operator is suggested to lift up unload lever(safety lock lever).