II-169
WSM Minor Change II Service Engineering Section
2-3 Erasing Method of Error Log
The error log will be deleted by selecting Error Log Delete in Diagnosis Mode. In the software, only the 0th to
third bits (the accumulated number of errors) in EEPROM addresses 85 through 103 will be zero cleared,
but hour meter data will not be zero cleared. Error Log Delete in Diagnosis Mode judges that there is no
error log if the number of errors is zero.
Hour meter data will not be deleted after executing Error Log Delete in Diagnosis Mode. Therefore, by
dumping the EEPROM, hour meter data for errors will be known. This will make troubleshooting possible if
the LCD meter is returned to the factory due to a failure after shipping.
The contents of addresses 65 through 103 are zero cleared with the PC before shipping.
Fig.2.Address and contents of EEPROM
Ref.1 : 0:KX41-3, 1:KX61-3, 2:KX71-3, KX91-3, 4:KX101-3, 5:KX-121-3, 6:KX161-3, ···
Ref.2 :
Address No. Contents & purpose to use
0
35
Hour meter
36 Machine model (Ref.1)
37 Optional item (Ref.2)
38
44
AI control data
45
50
Thumb control data
51
52
Overheat control data
53 Language (Ref.3)
54
63
Machine hours & times
64
104
Machine failure warning
105
127
Original manufacturer use
Address No. 118 : Machine serial No.
~~~~~~
8bit No : 7 6 5 4 3 2 1 0
0 : Made in Japan, 1 : made in Germany
0 : Non AI, 1 : AI - version
1 : Chinese - version
1 : Thumb - version
1 : Anti - theft - version
1 : K or U - version
1 : Japanese - version, 0 : Oversea’s - version
1 : Long arm
0 : Canopy, 1 : Cab