EasyManuals Logo
Home>KYMCO>Scooter>DINK 200

KYMCO DINK 200 User Manual

KYMCO DINK 200
225 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #193 background imageLoading...
Page #193 background image
16. BATTERY/CHARGING SYSTEM
16-2
DINK 200
SERVICE INFORMATION
GENERAL INSTRUCTIONS
The battery can be charged and discharged repeatedly. If a discharged battery is not used for a
long time, its service life will be shortened. Generally, the capacity of a battery will decrease after
it is used for 2_ 3 years. A capacity-decreased battery will resume its voltage after it is
recharged but its voltage decreases suddenly and then increases when a load is added.
When a battery is overcharged, some symptoms can be found. If there is a short circuit inside the
battery, no voltage is produced on the battery terminals. If the rectifier won‘t operate, the
voltage will become too high and shorten the battery service life.
If a battery is not used for a long time, it will discharge by itself and should be recharged every 3
months.
A new battery filled with electrolyte will generate voltage within a certain time and it should be
recharged when the capacity is insufficient. Recharging a new battery will prolong its service life.
Inspect the charging system according to the sequence specified in the Troubleshooting.
Do not disconnect and soon reconnect the power of any electrical equipment because the electronic
parts in the regulator/rectifier will be damaged. Turn off the ignition switch before operation.
It is not necessary to check the MF battery electrolyte or fill with distilled water.
Check the load of the whole charging system.
Do not quick charge the battery. Quick charging should only be done in an emergency.
Remove the battery from the motorcycle for charging.
When replacing the battery, do not use a traditional battery.
When charging, check the voltage with an electric tester.
SPECIFICATIONS
Item
Standard
Capacity
12V8AH
Voltage
Fully charged
13.2V
Battery
(20 )
Undercharged
12.3V
Charging current
STD: 0.9A Quick: 4.0A
Charging time
STD: 5-10hr Quick: 30min
Capacity
160W/500rpm
A.C. Generator
Charging coil resistance (20 )
Yellow_ Yellow
0.6_ 1.6Ω
Charging rpm
1300rpm max (14V)
Charging performance
6A min/2500rpm 8A min/5000rpm
Regulator/Rectifier
Limit voltage
14.5±0.5V
TESTING INSTRUMENTS TORQUE VALUES
Ammeter Pulser coil bolt 0.5kg-m
Electric tester Coil lock bolt 0.9kg-m
Tachometer Flywheel nut 3.5_ 4.5kg-m
The battery electrolyte (sulfuric acid) is poisonous and may seriously damage the skin and
eyes. Avoid contact with skin, eyes, or clothing. In case of contact, flush with water and get
prompt medical attention

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KYMCO DINK 200 and is the answer not in the manual?

KYMCO DINK 200 Specifications

General IconGeneral
BrandKYMCO
ModelDINK 200
CategoryScooter
LanguageEnglish

Related product manuals