42
4.2.3. Installation Worksheets
4.2.3.1. Cooling/HeatingwithElectricStripHeat(Non-HeatPump)
Job Name:
Indoor Unit Model:
Outdoor Unit Model:
CBX32MV, Rev 6 or higher, CBX40UHV and CBA38MV Indoor Unit Setup:
9 Cut on-board link R to DS “DEHUM or HARMONY”
9 Remove any factory-installed jumpers bars from W1 to W2 or W2 to W3.
9 Air handler control jumper settings:
Function Settings Condition
COOL
This setting, along w/ ADJUST setting, determines maximum system
CFM (See blower tables)
ADJUST
Setting affects both heating and cooling blower speeds (see blower
tables to determine setting)
HEAT HIGH Heating blower speed selection – Ignored by Harmony III zoning system
DELAY 4 Cooling blower ramping – Ignored by Harmony III zoning system
BLOWER
ONLY CFM
Continuous fan speed – Ignored by Harmony III zoning system
EVENHEAT EVENHEAT is not used with Harmony III zoning system
Panel Setup:
9 Heating staging jumper Circle one: 85 90 100
110 120 130
Recommended 120 deg-F
9 Zone 1 PIAB 140F DAS
jumper in place
Circle one: Yes No See “1.10.4. Zone 1 PIAB Jumpers
– 140ºF DAS” on page 10.
9 Cooling staging jumper Circle one: 50 55 60 Select desired discharge air temp
during cooling
9 Cont. Air Reduction jumper Circle one: 0 25 50 75 Percentageairowreductionfor
continuous fan operation
9 Heating Air Reduction
jumper
Circle one: 0 20 40 Percentageairowreductionfor
heating mode
9 SystemConguration
jumpers
Circle one: HP GAS Set to GAS
9 Stages Circle one: 2COOL
1COOL
Set to match condenser, 1 or 2
stage
9 Stages Circle one: 2HP 1HP Ignored for gas heat, non-heat
pump application
9 E-HEAT Stages Circle one: DF 1 2 3 Ignored for gas heat, non-heat
pump application
9 Desired total system CFM
with all zones calling:
Total system CFM per
tables:
Minimum CFM:
9 Zone 1 Name: Desired CFM: PIAB Setting: Actual CFM:
9 Zone 2 Name: Desired CFM: PIAB Setting: Actual CFM:
9 Zone 3 Name: Desired CFM: PIAB Setting: Actual CFM:
9 Zone 4 Name: Desired CFM: PIAB Setting: Actual CFM:
Field Wiring Checklist
Indoor Unit Wiring Completed:
DS on Harmony III to DS on indoor unit connected
C on indoor unit connected to Harmony III transformer C,
No connection to Y1 or Y2 on indoor unit.
Outdoor Unit Wiring Completed
Thermostat and Damper Wiring Completed
Discharge Sensor wired to Harmony III zoning system

Table of Contents

Other manuals for Lennox Harmony III