Basic units in the power range of 15 ... 90 kW
Terminal assignment - Application I/ O E82ZAFA
7
Extensions for automation
7.4
7.4.4
L
7.4-9
EDS82EV903-1.0-11/2002
7.4.4 Terminal assignment - Application I/O E82ZAFA
)
))
) Note!
Shield control cables to avoid interferences!
0
1 2
3
4
5
E82ZAFA020 / E82ZAFX009
Fig. 7.4-5 Front and rear view
0
E82ZAFAC function module
1
Terminal strip X3.1, analog inputs
2
Terminal strip X3.2, analog outputs
3
Terminal strip X3.3, digital inputs and outputs
4
Jumper for configuring analog inputs and outputs
5
Nameplate
Electrical connection Terminal strip with screw connection
Possible connections
rigid: 1.5 mm
2
(AWG 16)
flexible:
without wire crimp cap
1.0 mm
2
(AWG 18)
with wire crimp cap, without plastic sleeve
0.5 mm
2
(AWG 20)
with wire crimp cap, with plastic sleeve
0.5 mm
2
(AWG 20)
Tightening torque 0.22 ... 0.25 Nm (1.9 ... 2.2 lb-in)
Bare end 5mm
Screw terminal data
Show/Hide Bookmarks

Table of Contents

Other manuals for Lenze 8200 vector

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8200 vector and is the answer not in the manual?

Lenze 8200 vector Specifications

General IconGeneral
BrandLenze
Model8200 vector
CategoryDC Drives
LanguageEnglish

Related product manuals