Operation with rated power (normal operation)
Rated data for mains voltage 230 V
4
Technical data
4.3
4.3.1
L
4.3-2
EDS82EV903-1.0-11/2002
Typical motor p ower
P
r
[kW] 0.55 0.75 1.5 2.2
Three-phase
C asynchronous motor
(4 pole)
P
r
[hp] 0.75 1.0 2.0 3.0
8200 vector type EMC filter
integrated
E82EV551K2C0xx E82EV751K2C0xx E82EV152K2C0xx E82EV222K2C0xx
Without EMC filter E82EV551K2C2xx E82EV751K2C2xx E82EV152K2C2xx E82EV222K2C2xx
Mains voltage U
mains
[V] 1/N/PE A C 180 V - 0 % ... 264 V + 0 % ; 45 Hz - 0 % ... 65 Hz + 0 %
3/PE AC 100 V - 0 % ... 264 V + 0 % ; 45 Hz - 0 % ... 65 Hz + 0 %
Alternative DC supply U
DC
[V] DC 140 V - 0 % ... 370 V + 0 %
Data for operation with 1/N/PE (3/PE) AC 230 V or DC
325 V
1/N/PE 3/PE 1/N/PE 3/PE 1/N/PE 3/PE 1/N/PE
1)
3/PE
Rated mains current
without mains choke I
mains
[A] 6.0 3.9 9.0 5.2 15.0 9.1 - 12.4
with mains choke I
mains
[A] 5.6 2.7 7.5 3.6 12.5 6.3 18.0 9.0
Output power U, V, W S
r
[kVA] 1.2 1.6 2.8 3.8
Output power +U
G
,-U
G
2)
P
DC
[kW] - 0.3 - 0.1 - 1.1 - 0.4
Rated output current at 2kHzsin
chopper frequency
4kHzsin
I
r
[
]
3.0 4.0 7.0 9.5
8kHzsin I
r
[A] 3.0 4.0 7.0 9.5
16 kHz sin
4)
I
r
[A] 2.0 2.6 4.6 6.2
Max. permissible 2kHzsin
output current for 60 s
4kHzsin
I
max
[
] 4.5 6.0 10.5 14.2
at chopper frequency
3)
8kHzsin I
max
[A] 4.5 6.0 10.5 14.2
16 kHz sin
4)
I
max
[A] 2.9 3.9 6.9 9.3
Output voltage
without mains choke/mains f ilter U
M
[V] 3~ 0 ... V
mains
/ 0 ... 650 H z
with mains choke/mains filter U
M
[V] 3~ 0 ... approx. 94 % U
mains
/ 0 ... 650 H z
Power loss (operation with I
r8
) P
v
[W] 50 60 100 130
Required mains choke Type - - - ELN1-0250H018 -
Dimensions H x W x D [mm] 180 x 60 x 140 240 x 60 x 140
Weight m[kg] 1.2 1.6
Printed in bold = Data for operation at 8 kHz chopper frequency (Lenze setting)
1)
Operation only with mains choke
2)
For operation with power-adapted motors additional power to be t aken from the DC bus
3)
Currents for periodic load change : 1 min overcurrent with I
max
and 2 min basic load with 75 % I
r
4)
Chopper frequency is reduced to 4 kHz if Ï‘
max
reaches - 5 °C
5)
With different application conditions for other types possible: Operation with increased rated output current and
the same load change
(¶ 4.4-1)