Function library
Function blocks
3.5.56 Ramp function generator (RFG)
3−246
l
EDSVS9332P−EXT DE 2.0
3.5.56 Ramp function generator (RFG)
Purpose
The ramp function generator limits the rise of signals.
C0671
C0672
C0676/1
RFG1
RFG1-OUT
RFG1-IN
C0676/2
1
0
RFG1-SET
C0677
RFG1-LOAD
C0673
C0674
C0675
Fig. 3−194 Ramp function generator (RFG1)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
RFG1−IN a C0676/1 dec [%] C0673 1 1000
RFG1−SET a C0676/2 dec [%] C0674 1 1000
RFG1−LOAD d C0677 C0675 2 1000
RFG1−OUT a
Function
l Calculation and setting of the times T
ir
and T
if
l
Loading of the ramp function generator