Protocol Description


The receiver accepts commands surrounded by curly brackets - { } - and responds data surrounded by
round brackets - ( ) - only if a command was successfully executed. All input commands are converted to
uppercase, but respond commands can contain upper and lower case letters as well.
Legend for Control Commands
Format Explanation
<in> 
<out> Output number in 1 or 2 digit ASCII format
 input or output port number in 1 or 2 digit ASCII format *
<in2> Input number in 2 digit ASCII format (01, 02, 10, 12 etc.)
<out2> Output number in 2 digit ASCII format (01, 02, 10, 12 etc.)
 input or output number in 2 digit ASCII format*
<loc> 
<id> id number in 1 or 2 digit ASCII format
<id2> id number in 2 digit ASCII format
 
· Space character (0x20)
→
Each command issued by the controller
Each response received from the router
* The command has the same arguments on the input ports and the output port, as well.
Instructions for the Terminal Application Usage
Terminal Application

receiver using a terminal application. You need to
install one of them on your control device, for example
Putty or CLI. #terminal
Establishing Connection
Follow the steps for establishing connection to the
receiver:
Step 1. 
Step 2. Open the terminal application (e.g. Putty).
Step 3. Add the IP address of the device (default:
192.168.0.100) and the port number (10001).
Step 4. Select the Raw connection type, and open the
connection.
Once the terminal window is opened, you can enter

following sections.
LW2 protocol command communication in a terminal window

Table of Contents

Other manuals for Lightware MMX4x2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lightware MMX4x2 Series and is the answer not in the manual?

Lightware MMX4x2 Series Specifications

General IconGeneral
BrandLightware
ModelMMX4x2 Series
CategoryMatrix Switcher
LanguageEnglish

Related product manuals