Rev:11.08.19 Page 124 CCD-0001573-08
Troubleshooting
What Is Happening? Why? What Should Be Done?
System will not turn on and
the on/off indicator light
does not illuminate.
Coach ignition is not in RUN
position.
Turn ignition to RUN position.
Touch pad has been on for
more than 4 minutes and
has timed out.
Turn ignition OFF and then back ON.
Touch pad turns on
but turns off when jack
directional buttons are
pressed or touch pad
displays "low voltage."
Blown fuse. Check and replace faulty fuse(s).
Low voltage on battery. Start coach to charge battery.
Touch pad turns on, coach
will not auto-level, "Jacks
Down" displayed, jacks are
retracted.
Low fluid level.
Check fluid level in reservoir, if fluid is low,
add fluid to
½
" from top of reservoir with
jacks retracted. If "JACKS DOWN" light
remains on, call Customer Service.
Jacks will not extend to
ground, pump is running.
Little or no fluid in reservoir. Add fluid as recommended.
Cartridge valve is
inoperative.
Clean, repair, or replace.
Electronic signal is lost
between controller and
solenoid.
Trace wires for voltage drop or loss and
valves signal. Repair or replace necessary
wires or replace control pad.
Any one or two jacks will
not retract.
Hose damaged or
unconnected.
Replace with new hose or reconnect hose.
Cartridge valve inoperative. Replace inoperative cartridge valve.
Electronic signal is lost
between controller and
solenoid.
Attempt to retract jacks in MANUAL mode.
If successful, replace touch pad; if not,
test for voltage drop between touch pad
control and valve, repair bad wiring or
replace defective board or valve.
"READY - Jacks: Up" does
not display when all jacks
are retracted.
Low fluid level. Add fluid as recommended.
Retract pressure switch
inoperable.
Check connection or replace pressure
switch.
Alarm sounds and "Jacks
Down" light starts flashing
while traveling; jacks are
fully retracted.
Low fluid level. Add fluid as recommended.
Retract pressure switch
inoperable.
Check connection or replace pressure
switch.
Coach drifts down after
jacks are extended. Jack
bleeds down after being
retracted.
Possible fluid leak.
Check for fluid leaks and repair or replace
components as necessary.
Valve manual override open.
Close override, see Manual Override of The
Power System and Jacks.
Touch pad powers up;
screen displays "Low
Voltage."
Loose ground wire at power
unit.
Check for loose wires.
Engine not running. Start coach engine.
No power to touch pad.
Tripped circuit breaker. Reset.
Circuit protection tripped. Replace circuit protection.
Ignition not "ON". Turn ignition "ON".
Auto level function does
not finish.
Error code "Unable to finish
leveling."
Move coach to a more level site.