Rev:11.08.19 Page 150 CCD-0001573-08
Troubleshooting
Error Display In LCD Screen
To clear an Error Code, repair, correct the issue or press ENTER button (Fig. 1C). If the error remains, the error
message will reappear.
Error Codes
LCD Message What's Happening? What Should Be Done?
"EXCESS ANGLE"
Controller not properly secured.
Check and secure controller placement.
Excessive angle reached during auto operation.
Relocate the 5th Wheel.
"EXCESSIVE ANGLE"
Controller not properly secured.
Check and secure controller placement.
Excessive angle reached during manual operation.
Relocate the 5th Wheel.
"FEATURE DISABLED"
Front of 5th Wheel below level when starting auto-level
process (only when trying to initiate Hitch Recognition).
Push the FRONT Button to raise the 5th Wheel up to hitch
height and connect to tow vehicle.
Touchpad power not cycled between consecutive
leveling operations.
Turn touchpad off and then back on to reset the system.
Zero Point not set.
Set Zero Point.
"LOW VOLTAGE"
Battery voltage dropped below 9.5V.
Check wiring - repair or replace.
Test battery voltage under load - charge or replace.
"OUT OF STROKE"
Jack has reached maximum stroke length and is
unable to lift.
Check disposition of jacks and/or relocate the 5th Wheel.
"EXTERNAL SENSOR"
Bad connection or wiring from the controller to
the sensor.
Replace or repair connection to rear remote sensor.
"JACK TIME OUT"
Time limit exceeded for the requested auto operation.
Check disposition of jacks.
"AUTO LEVEL FAIL"
Unable to auto-level due uneven ground.
Check disposition of jacks and/or relocate the 5th Wheel.
Unable to auto-level due to Zero Point being
set incorrectly.
Reset zero point.
"BAD CALIBRATION"
Sensor calibration values are out of range.
Replace controller.
"INTERNAL SENSOR"
Internal sensor problem.
Replace controller.
**PANIC STOP**
"FUNCTION ABORTED"
The User pressed a button on the touchpad during an
automatic operation.
Restart automatic operation and then refrain from
pressing any buttons on the touchpad.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lippert Components PSX2 and is the answer not in the manual?

Lippert Components PSX2 Specifications

General IconGeneral
BrandLippert Components
ModelPSX2
CategoryLifting Systems
LanguageEnglish

Related product manuals