Rev:11.08.19 Page 22 CCD-0001573-08
Touch Pad Error Codes
NOTE: To clear an error code from the touch pad, repair or otherwise correct the issue, then press “ENTER.” If
the error is still present, the message will be displayed again.
LCD Message What's Happening? What Should Be Done?
****ERROR****
Excess Angle
Controller not properly secured. Check and secure controller placement.
Excessive angle reached during
auto operation.
Relocate the trailer.
****ERROR****
Excessive Angle
Controller not properly secured. Check and secure controller placement.
Excessive angle reached during
auto operation.
Relocate the trailer.
****ERROR****
Feature Disabled
Front of trailer below level when
starting Auto Level process (only
when trying to initiate Hitch
Recognition).
Using manual mode on the touch pad, retract rear
(which includes the middle, if equipped) jacks and
set landing gear (front jacks) to hitch height.
Touch pad power not cycled
between consecutive leveling
operations.
Turn touch pad off and then back on to reset the
system.
Zero point not set. Set zero point.
****ERROR****
Low Voltage
Battery voltage dropped below
10.8V.
Check wiring - repair or replace.
Test battery voltage under load - charge or replace.
****ERROR****
Out Of Stroke
Jack has reached maximum stroke
length and is unable to lift.
Check disposition of jacks. Relocate the trailer.
Unexpected high amp current stall.
Check jacks in manual mode or perform manual
override procedure. Repair or replace as needed.
Check for bent or damaged jacks. Repair or replace
as needed.
****ERROR****
External Sensor
Bad connection or wiring from the
controller to the rear sensor.
Replace or repair connection to rear remote sensor.
****ERROR****
Jack Time Out
Time limit exceeded for the
requested auto operation.
Check disposition of jacks.
****ERROR****
Auto Level Fail
Unable to auto level due to uneven
ground.
Check disposition of jacks. Relocate the trailer.
Unable to auto level due to zero
point being set incorrectly.
Reset zero point.
****ERROR****
Comm Error
Communication between controller
and touch pad has been lost.
Check harness for proper connections or damage.
Replace if necessary.
****ERROR****
Bad Calibration
Sensor calibration values are out of
range.
Replace controller
****ERROR****
Internal Sensor
Internal sensor problem. Replace controller
**PANIC STOP**
Function Aborted
The user pressed a button on the
touch pad during an automatic
operation.
Restart automatic operation and then refrain from
pressing any buttons on the touch pad.
****ERROR****
Hall Effect Short
Short circuit detected in one of the
hall effect circuits.
Test for short and repair or replace.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lippert Components PSX2 and is the answer not in the manual?

Lippert Components PSX2 Specifications

General IconGeneral
BrandLippert Components
ModelPSX2
CategoryLifting Systems
LanguageEnglish

Related product manuals