What Is Happening? Why? What Should Be Done?
Switch does not
activate system.
Low voltage.
Test battery voltage under load. Charge or replace.
Use Manual Override.
Damaged or
disconnected wiring.
Check wiring. Repair or replace.
Use Manual Override.
Tripped or blown circuit
protection.
Reset or replace circuit protection.
Jacks will not extend to
ground while pump is
running.
Little or no fluid in
reservoir.
Add fluid as recommended.
Cartridge valve is
inoperative.
Clean, repair or replace cartridge valve.
Hose damaged or
unconnected.
Replace with new hose or reconnect hose.
Jacks will not retract
while pump is running.
Little or no fluid in
reservoir.
Add fluid as recommended.
Cartridge valve is
inoperative.
Replace inoperative cartridge valve.
Hose damaged or
unconnected.
Replace with new hose or reconnect hose.
Trailer bleeds down
after jacks extended.
Possible fluid leak.
Check for fluid leaks and repair or replace
components as necessary.
Cartridge valve manual
override open.
Close override. See Manual Override of the system.
Jack bleeds down after
being retracted.
Possible fluid leak.
Check for fluid leaks and repair or replace
components as necessary.
Cartridge valve manual
override open.
Close override. See Manual Override of the system.
Troubleshooting
Troubleshooting Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lippert Components PSX2 and is the answer not in the manual?

Lippert Components PSX2 Specifications

General IconGeneral
BrandLippert Components
ModelPSX2
CategoryLifting Systems
LanguageEnglish

Related product manuals