EasyManuals Logo
Home>Manitowoc>Construction Equipment>18000

Manitowoc 18000 User Manual

Manitowoc 18000
302 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #124 background imageLoading...
Page #124 background image
Reference Only
OPERATING CONTROLS AND PROCEDURES 18000 OPERATOR MANUAL
3-64
Published 12-05-17, Control # 032-23
• REMOTE TRAFFIC where bank one is transmitter
identification and bank two property code of hand-held
radio remote. The two banks work together and
continuously display information for each radio remote in
immediate area.
NOTE: Cranes with 2.4 Ghz wireless systems will not
display traffic information.
Block Level Sensor
The LEVEL screen displays the following information:
BLOCK LEVEL SENSOR - where the block identification
code is entered and displayed. To enter a block identification
code, press select. The cursor (*) appears next to Block
Level Sensor. Press select again to enter identification code
area. Scroll up or down to enter 0 to 9, press select to move
through each four positions.
BLOCK ANGLE - where the block angle is displayed. A block
level fault occurs if the maximum block angle for parts of line
is exceeded:
Crane Mode
The crane mode screen displays the selected crane mode:
• Crane mode
• PROG is computer program version
• CON is computer and crane configuration code
Hydraulic Fan (Tier 4 only)
The hydraulic fan screen displays the following information
for the Tier 4 hydraulic fan system:
• PRESS – Fan system pressure. Increased cooling
demand and increased engine speed will increase this
pressure.
• PUMP – Displays the current pump command. This will
range from 5 to 100% and change in response to cooling
demand and engine speed.
• STATUS – Displays the error status of the fan system:
0 = no fault
Bit 1 = fan pressure transducer out of range
Bit 2 = fan control valve digital output fault
Bit 3 = fault is set if fan pressure is below 500 psi (34,5
bar) after the system is initialized. Will cause the backup
coil to energize and try to fully stroke the pump.
*BLOCK LEVEL SENSOR
BLOCK ANGLE
DRUM 1 PUMP
DRUM 2 PUMP
+ 3.43 DEG
30 %
31 % LEVEL
Angle in Degree Parts of Line
10 16 or less
8.8 20
7.6 24
6.4 28
5.2 32
4.0 36
Crane Mode - STANDARD
PROG M0000000.ONP CON 000000
PRESS 000 PSI
PUMP 0 %
STATUS 0
HYRAULIC FAN

Table of Contents

Other manuals for Manitowoc 18000