Grove Published 3-25-2020, Control # 595-10 5-27
GRT8100 OPERATOR MANUAL MAINTENANCE AND LUBRICATION
5
Item
Lube Point
Description
Figure No.
Approved
Lubricant
Lube
Capacity
Lube Interval Application
Hoist
100 Main Hoist
Figure<$pa
ranum>
B
4.7 L
(5.0 qt)
Check and fill every
50 hours or weekly
Drain and fill every
1000 hours or 12
months
Oil level must be
between the high and
low marks on the sight
glass.
101 Auxiliary Hoist
Figure<$pa
ranum>
B
4.7 L
(5.0 qt)
Check and fill every
50 hours or weekly
Drain and fill every
1000 hours or 12
months
Oil level must be
between the high and
low marks on the sight
glass.
NOTE: Hoist oil level must be between the high and low marks on the sight glass (100, 101). Remove the plug or hose
from the bottom of the sight glass to drain oil. Remove the vent or hose from the top of the sight glass to add oil.
102
Cable Roller
(Arms)
Figure<$pa
ranum>
A
Thoroughly
coat
250 hours or 3 months Brush on
103 Hoist Bearing
Figure<$pa
ranum>
A
Until grease
extrudes
250 hours or 3 months 2 Grease Fittings
NOTE: Lubricate more frequently than interval indicated if environmental and/or operating conditions required.
FRONT
FRONT
102
102
103
103
FIGURE 5-15
8618
8619
100
101

Table of Contents

Other manuals for Manitowoc Grove GRT8100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GRT8100 and is the answer not in the manual?

Manitowoc Grove GRT8100 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GRT8100
CategoryConstruction Equipment
LanguageEnglish

Related product manuals